2.3 Tab TEACH TABLE
When the GO button is pressed, data transfer from the sensor to the PC is started. The respective RED, GREEN,
and BLUE contents are shown by way of the bars beside the graph. The calculated X, Y, INT or s,i,M values are
visualised in the displays.
X or s:
This numerical value output field displays the RED content (x-axis) of the scattered light
currently arriving at the receiver.
Y or i:
This numerical value output field displays the GREEN content (y-axis) of the scattered
light currently arriving at the receiver.
INT or M:
This numerical value output field displays the currently measured intensity (proportional to
the average of the intensities at the triple receiver).
C-No.:
This numerical value output field displays the currently detected color number in accordance with
the entry in the TEACH TABLE. The currently detected color number is sent to the digital outputs
OUT0 … OUT4 as a corresponding bit pattern.
The value 255 means that none of the taught colors is recognised.
A double-click on the display opens a larger display window.
Please note: The above-mentioned output fields are only updated when data transfer between PC
and colorSENSOR OT-3-...-200-20 color sensor is active (GO button pressed).