The baudrate for data transfer through the RS232 interface can be
set by means of the SELECT BAUDRATE drop down menu and
CHANGE BAUDRATE function field.
This is necessary if a high-speed connection is needed for data
transfer through the serial interface.
If the baudrate should be changed, a connection must first be
established by clicking on TRY TO CONNECT.
The CHANGE BAUDRATE button will then be active.
Now a new baudrate can be selected under SELECT BAUDRATE.
A click on CHANGE BAUDRATE sends the new baudrate
information to the sensor.
When the new baudrate information has
been successfully sent, the sensor
operates with the new baudrate. A window
will pop up, prompting you to select
EEPROM and then to press SEND. After a
hardware reset the new baudrate only will
be used when EEPROM and SEND have
been pressed.
A click on ACCEPT SETTINGS saves the
current interface settings, which will then be
automatically set when the software is
restarted.