Auto Page MA-200 Bedienerhandbuch Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
colorCONTROL C4
46
Example 6: DATA FRAME with ORDER NUMBER = 6:
ORDER NUMBER (second word = 6): SAVE parameters from RAM to EEPROM of the sensor!
The complete data frame = 18 words must be sent to the sensor in binary form
(sync-word / order-word / 16 parameter words).
DATA FRAME PC Æ Sensor (18 WORDS)
0x0055 SYNC.-WORD
6 ORDER-WORD
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
After sending this data frame, the sensor saves all the parameters and teach vectors from its RAM (volatile
memory) to its EEPROM (non volatile memory).
ATTENTION: The right parameters and teach vectors must be in the RAM of the sensor. To save the parameters
and teach vectors into RAM see Example 1 and Example 2.
After completing the sensor writes back an echo of the same frame.
DATA FRAME Sensor Æ PC (18 WORDS)
0x00AA SYNC-WORD
6 ORDER-WORD
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
0 DUMMY
Seitenansicht 46